Cryogenic funcional testing

Cryogenic funcional testing

Cryogenic Test is a special test used to test the tightness of the valve (both floating and trunnion versions) at low temperatures from -36°C to -196°C with liquid nitrogen.
The cryogenic valve is tested at the operating pressure and temperature specified by its class.

CRYOGENIC TEST DESCRIPTION
Valve Leak Test

  • Placement of the valve in the cryogenic tank and verification of all connections.
  • Slow insufflation of liquid nitrogen in cryogenic tank.
  • When the required temperature is reached, test gas is fed into the valve at the pressure indicated by the test procedure.
  • During the test, any leaks to the outside world are detected and quantified by a leak detector, the Sniffer (testing instrument).
  • Any internal leaks, on the other hand, are detected in the classical way with pressure gauges and bubble counters.
  • The temperature is kept constant and is monitored by a thermocouple inserted inside the valve, which shows the exact value in °C on a display.
  • At the end of the test, a report is generated, and the valve is depressurized and gradually brought to room temperature.